DocumentCode
3385694
Title
An improved method/setup for extended testing after the Cigre, Method II
Author
Henriksen, M. ; Holboll, J.T. ; Rygal, Roman
Author_Institution
Dept. of Electr. Power Eng., Tech. Univ. of Denmark, Lyngby, Denmark
fYear
1992
fDate
7-10 Jun 1992
Firstpage
144
Lastpage
148
Abstract
The authors describe an improved version of the Cigre Method II test techinque used for testing the resistance of insulating materials to partial discharges (PDs). The method was extended to continuous PD measurements and pulse analyses. It was sound that parameters such as selective fuse protection of the different test objects, and the sample production and preparation, among others, were of the utmost importance for the end results of this test. Results of using the system on epoxy with and without fillers are presented. Based on these results, the critical points of the method are discussed. The application of the system showed typical behavior of the discharges and lifetimes that was strongly dependent on the filler type
Keywords
ageing; filled polymers; insulation testing; organic insulating materials; partial discharges; Al2O3 filled epoxy; Cigre Method II test techinque; SiO2 filled epoxy; ageing time; continuous PD measurements; insulation resistance testing; partial discharges; pulse analyses; selective fuse protection; Automatic testing; Breakdown voltage; Electric resistance; Electrodes; Fuses; Materials testing; Partial discharges; Protection; System testing; Time measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation, Conference Record of the 1992 IEEE International Symposium on
Conference_Location
Baltimore, MD
ISSN
1089-084X
Print_ISBN
0-7803-0649-X
Type
conf
DOI
10.1109/ELINSL.1992.247033
Filename
247033
Link To Document