Abstract :
300MW unit is taken for example in this paper, two calculation methods are used in heat balance calculation. One is that No.8 low-pressure heater, gland heater and condenser hot well are regarded as a whole to list heat balance equation, and the other is that only No.8 low-pressure heater is regarded as a whole to list heat balance equation. Then, the paper analyses and compares difference between two calculated results under conditions of steam turbine load variation and emergency drainage occurs in low-pressure heater. Meanwhile, in view of drainage flash evaporation in condenser hot well, the calculation method with respect to heater´s drainage flash evaporation is given. The conclusions are significant to further improve the accuracy of steam turbine thermal system calculation and study the change mechanism of steam turbine heat economy.
Keywords :
condensers (steam plant); steam power stations; steam turbines; condenser; condenser hot well; emergency drainage; gland heater; gland heater disposal method; heat balance calculation; heater drainage flash evaporation; no.8 low-pressure heater; power 300 MW; steam turbine heat economy; steam turbine load variation; steam turbine thermal system calculation; unit thermal economy; Approximation algorithms; Equations; Glands; Mathematical model; Turbines; Water heating;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power and Energy Engineering Conference (APPEEC), 2012 Asia-Pacific
Conference_Location :
Shanghai
ISSN :
2157-4839
Print_ISBN :
978-1-4577-0545-8
Type :
conf
DOI :
10.1109/APPEEC.2012.6307017
Filename :
6307017
Link To Document :
بازگشت