  • Abstract
    The application of a solder bump technique for contacting a multi electrode sensor/actuator system is presented. Techniques adapted from the literature could successfully be scaled down to 55×55 μm bumps at 120 μm heart-to-heart spacing
  • Keywords
    arrays; bioelectric phenomena; biological techniques; microactuators; microelectrodes; neurophysiology; soldering; 120 mum; CMOS chip; Si; buffer amplifiers; current sources; epoxy-embedded needles; heart-to-heart spacing; insulated needle shafts; intraneural recording; intraneural stimulation; iridium oxide electrode; multielectrode sensor/actuator system; multiplexers; nickel pads array; silicon needles; solder bump technique; three-dimensional multielectrode array contacting; Aluminum; Biomedical electrodes; Chromium; Copper; Etching; Needles; Nickel; Resists; Silicon; Tin;