  • Abstract
    A model for predicting force production, about the elbow using the surface EMG (SEMG) is presented. The EMG-force relationship was modeled for static (isometric) and dynamic (constant velocity) concentric contractions (both flexion and extension) about the elbow
  • Keywords
    biocontrol; biomechanics; electromyography; force control; medical signal processing; physiological models; EMG to force model; EMG-force relationship; dynamic constant velocity concentric contractions; extension; flexion; force production; human elbow; static isometric concentric contractions; surface EMG parameters; Angular velocity; Elbow; Electromyography; Force measurement; Humans; Muscles; Predictive models; Production; Signal processing; Transducers;