DocumentCode
3399144
Title
An EMG to force model for the human elbow derived from surface EMG parameters
Author
Misener, D.L. ; Morin, E.L.
Author_Institution
Dept. of Electr. & Comput. Eng., Queen´´s Univ., Kingston, Ont., Canada
Volume
2
fYear
1995
fDate
20-23 Sep 1995
Firstpage
1205
Abstract
A model for predicting force production, about the elbow using the surface EMG (SEMG) is presented. The EMG-force relationship was modeled for static (isometric) and dynamic (constant velocity) concentric contractions (both flexion and extension) about the elbow
Keywords
biocontrol; biomechanics; electromyography; force control; medical signal processing; physiological models; EMG to force model; EMG-force relationship; dynamic constant velocity concentric contractions; extension; flexion; force production; human elbow; static isometric concentric contractions; surface EMG parameters; Angular velocity; Elbow; Electromyography; Force measurement; Humans; Muscles; Predictive models; Production; Signal processing; Transducers;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 1995., IEEE 17th Annual Conference
Conference_Location
Montreal, Que.
Print_ISBN
0-7803-2475-7
Type
conf
DOI
10.1109/IEMBS.1995.579643
Filename
579643