Abstract
Along with the development of electric power system and the wide application of nonlinear equipments or devices, the harmonics in power networks become more complicated, and the interharmonics is more severe gradually. Dq transform and MUSIC algorithm is used to detect the frequency of interharmonics in this paper. The high amplitude fundamental waveform can be eliminated by dq transform. MUSIC algorithm is kinds of the subspace spectrum estimation methods having no requires for synchronous sampling, which is suitable for short-term stable interharmonic detection. Combination of both can effectively detect low interharmonic beside high amplitude fundamental waveform. The joint algorithm is robust when interharmonic-level noise is present. Finally, the amplitudes and phases of signal are estimated by the least squares method.
Keywords
least squares approximations; power apparatus; power supply quality; power system harmonics; signal classification; wavelet transforms; DQ transform; MUSIC algorithm; electric power system; fundamental frequency; interharmonic level noise; interharmonic measurement; least squares method; nonlinear equipment; power network; subspace spectrum estimation method; Harmonic analysis; Multiple signal classification; Noise; Power system harmonics; Time frequency analysis; Transforms;
fLanguage
English
Publisher
ieee
Conference_Titel
Power and Energy Engineering Conference (APPEEC), 2012 Asia-Pacific
Conference_Location
Shanghai
ISSN
2157-4839
Print_ISBN
978-1-4577-0545-8
Type
conf
DOI
10.1109/APPEEC.2012.6307685
Filename
6307685
Link To Document