DocumentCode
340237
Title
A novel APD-based detector module for multi-modality PET/SPECT/CT scanners
Author
Saoudi, A. ; Lecomte, R.
Author_Institution
Metabolic & Functional Imaging Center, Sherbrooke Univ., Que., Canada
Volume
2
fYear
1998
fDate
1998
Firstpage
1089
Abstract
The lack of anatomical information in SPECT and PET images is one of the major factors limiting the ability to localize and accurately quantify radionuclide uptake in small regions of interest, This problem could be resolved by using multi-modality scanners having the capability to acquire anatomical and functional images simultaneously. The feasibility of a novel detector suitable for detecting high-energy annihilation radiation in PET, medium-energy γ-rays in SPECT and low-energy X-rays in transmission CT is demonstrated and its performance is evaluated for potential use in multi-modality PET/SPECT/CT imaging. The proposed detector consists of a thin CsI(Tl) scintillator sitting on top of a deep GSO/LSO pair read out by an avalanche photodiode. The GSO/LSO pair provides depth-of-interaction information for 511 keV detection in PET, while the thin CsI(Tl) that is essentially transparent to annihilation radiation is used for detecting lower energy X- and γ-rays. The detector performance is compared to that of an LSO/YSO phoswich. Although the implementation of the proposed GSO/LSO/CsI(Tl) detector raises special problems that increase complexity, it generally outperforms the LSO/YSO phoswich for simultaneous PET, SPECT and CT imaging
Keywords
avalanche photodiodes; caesium compounds; cerium; computerised tomography; diagnostic radiography; gadolinium compounds; lutetium compounds; positron emission tomography; single photon emission computed tomography; solid scintillation detectors; thallium; APD-based detector module; CsI:Tl; GSO/LSO/CsI(Tl) detector; GdSiO5:Ce; LSO/YSO phoswich; Lu2SiO4:Ce; avalanche photodiode; deep GSO/LSO pair; depth-of-interaction information; high-energy annihilation radiation; low-energy X-rays; multi-modality PET/SPECT/CT scanners; multi-modality scanners; radionuclide uptake; thin CsI(Tl) scintillator; Avalanche photodiodes; Computed tomography; Gamma ray detection; Gamma ray detectors; Image resolution; Optical imaging; Positron emission tomography; Radiation detectors; X-ray detection; X-ray detectors;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium, 1998. Conference Record. 1998 IEEE
Conference_Location
Toronto, Ont.
ISSN
1082-3654
Print_ISBN
0-7803-5021-9
Type
conf
DOI
10.1109/NSSMIC.1998.774353
Filename
774353
Link To Document