DocumentCode
3403062
Title
Eye-gaze detection based on the pupil detection technique using two light sources and the image difference method
Author
Ohtani, Masao ; Ebisawa, Yoshinobu
Author_Institution
Fac. of Eng., Shizuoka Univ., Hamamatsu, Japan
Volume
2
fYear
1995
fDate
20-23 Sep 1995
Firstpage
1623
Abstract
A new eye-gaze detection method was developed to use on a support system for the physically disadvantaged, such as amyotropic lateral sclerosis patients. This method was based on the pupil detection technique using two light sources and the image difference method. In this paper, hardware which detects the pupil and glint images (feature points for determining the eye-gaze) was developed. When wearing eye glasses, the system consisted of the image differentiator, the pupil detector including the noise reducer (dilation and erosion operations) and edge detector, the two circular moving window processors, the centroid detector and the glint edge detector. By using this system, the eye-gaze was detected even when the eye glass reflected light was seen in the images
Keywords
biomedical measurement; edge detection; eye; handicapped aids; infrared imaging; infrared sources; CCD camera; LED; amyotropic lateral sclerosis patients; centroid detector; dilation; edge detector; erosion operations; eye glasses; eye-gaze detection; feature points; glint edge detector; glint images; hardware; image difference method; image differentiator; noise reducer; physically disadvantaged; pupil detection technique; small near IR light source; support system; two circular moving window processors; two light sources; Cameras; Coaxial components; Detectors; Glass; Hardware; Head; Image edge detection; Light sources; Noise reduction; Windows;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 1995., IEEE 17th Annual Conference
Conference_Location
Montreal, Que.
Print_ISBN
0-7803-2475-7
Type
conf
DOI
10.1109/IEMBS.1995.579860
Filename
579860
Link To Document