• DocumentCode
    3404343
  • Title

    Start-up behaviour of the Doubly-Fed Induction Generator in a wind energy conversion system

  • Author

    Giaourakis, D.G. ; Safacas, A. ; Tsotoulidis, Savvas

  • Author_Institution
    Electr. & Comput. Eng. Dept., Univ. of Patras, Rio-Patras, Greece
  • fYear
    2013
  • fDate
    20-23 Oct. 2013
  • Firstpage
    127
  • Lastpage
    132
  • Abstract
    In this paper an investigation of the Doubly-Fed Induction Generator´s start-up procedure, using zero crossing method for the grid voltage´s angle´s calculation, is carried out in the environment of Matlab/ Simulink. Moreover, the significance of the phase displacement and the amplitude deviation of the stator voltage in the system´s synchronization procedure is highlighted via simulation.
  • Keywords
    asynchronous generators; stators; synchronisation; wind power plants; Matlab-Simulink; amplitude deviation; doubly-fed induction generator; grid voltage angle calculation; phase displacement; start-up procedure; stator voltage; synchronization procedure; wind energy conversion system; zero crossing method; Generators; Rotors; Stators; Synchronization; Voltage measurement; Wind speed; Wind turbines; doubly-fed induction generator; simulation; start-up; wind energy conversion;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Renewable Energy Research and Applications (ICRERA), 2013 International Conference on
  • Conference_Location
    Madrid
  • Type

    conf

  • DOI
    10.1109/ICRERA.2013.6749738
  • Filename
    6749738