DocumentCode
3405340
Title
Effects of data resolution on stand-alone hybrid system sizing
Author
Guler, O. ; Akdag, Seyit Ahmet ; Cakir, Yusuf Serdar
Author_Institution
Energy Inst., Istanbul Tech. Univ., Istanbul, Turkey
fYear
2013
fDate
20-23 Oct. 2013
Firstpage
423
Lastpage
427
Abstract
Generally, hourly measured source and load data are used to size stand-alone hybrid energy system. However, the power generated by wind turbines and PV panels change rapidly because of the continuous fluctuation of wind speed and solar radiation. Therefore, these fluctuations must be considered in sizing stand-alone hybrid energy system. On the other and, energy demand changes during the day. Within the context of the study, the effects of demand and sources data resolution on the stand-alone hybrid system sizing were analyzed considiring minutely and hourly sources and load data.
Keywords
hybrid power systems; photovoltaic power systems; power generation planning; wind power plants; energy demand; photovoltaic panel; sources data resolution; stand alone hybrid system sizing; wind turbines; Decision support systems; Renewable energy sources; Data resolution; Homer; Stand-alone hybrid system;
fLanguage
English
Publisher
ieee
Conference_Titel
Renewable Energy Research and Applications (ICRERA), 2013 International Conference on
Conference_Location
Madrid
Type
conf
DOI
10.1109/ICRERA.2013.6749792