Title : 
Plasma parameters after a forced extinguishing of the diffuse vacuum arc
         
        
        
            Author_Institution : 
Inst. of Electr. Power Eng., Wroclaw Univ. of Technol., Wroclaw
         
        
        
        
        
        
        
            Abstract : 
A series of experiments were performed in order to optimise the forced vacuum arc current commutation with the counter-pulse current method. The experiments were performed in a laboratory arrangement with parameters representatives for the low-voltage vacuum switches. The tested vacuum arc current with values 400 A and 600 A was interrupted with a counter-pulse current at falling rates from 2 A/mus up to 90 A/mus. The main measured parameters were: ion energy and residual charge after the current zero as function of the forced falling rate of the arc current. The results can be useful in modelling and design.
         
        
            Keywords : 
vacuum arcs; vacuum switches; counter-pulse current method; diffuse vacuum arc; ion energy; low-voltage vacuum switches; plasma parameters; residual charge; Charge measurement; Current measurement; Energy measurement; Force measurement; Laboratories; Optimization methods; Plasmas; Switches; Testing; Vacuum arcs;
         
        
        
        
            Conference_Titel : 
Discharges and Electrical Insulation in Vacuum, 2008. ISDEIV 2008. 23rd International Symposium on
         
        
            Conference_Location : 
Bucharest
         
        
        
            Print_ISBN : 
978-973-755-382-9
         
        
            Electronic_ISBN : 
1093-2941
         
        
        
            DOI : 
10.1109/DEIV.2008.4676804