Abstract :
As the limits on solid particulate emission become more severe in most industrialized countries, higher performance is required from electrostatic precipitation systems. It has been verified that by applying an impulse voltage instead of the conventional rectified voltage to the precipitator, the collection efficiency can be increased. To assess the benefit of the impulse energization with different coals, an experimental research was performed at a 35 MWe thermal power plant. Two technologies for the impulse power supplies were tested over 5000 hours of operation. The results of the tests, performed according to ASME standard, have show the great advantage of the impulse energization compared to the conventional energization in reducing the penetration factor to 1-2*10/sup -3/ with an absorbed power reduced from about 0.5 Wh/Nm/sup 3/ to about 0.1 Wh/Nm/sup 3/.<>
Keywords :
air pollution detection and control; coal; electrostatic precipitators; thermal power stations; 35 MW; air pollution control; coals; efficiency; electrostatic precipitators; impulse energization; impulse voltage; penetration factor; performance; power supplies; thermal power plant; Electrostatic precipitators; Impulse testing; Performance evaluation; Power generation; Power supplies; Solids; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industry Applications Society Annual Meeting, 1988., Conference Record of the 1988 IEEE
Conference_Location :
Pittsburgh, PA, USA
Type :
conf
DOI :
10.1109/IAS.1988.25282
Filename :
25282
Link To Document :
بازگشت