  • Abstract
    In this report, we present results of gain studies using various gas mixtures in a novel structure of gaseous detector called MICROMEGAS which is under development at Saclay. We in particular studied the maximum of gain achievable with MICROMEGAS before the discharge. We tried various gas mixtures (argon, neon, CF4) with various proportions of quencher (isobutane, cyclohexane, DME). We also studied the radiation hardness of MICROMEGAS using argon-isobutane and CF4 -isobutane mixtures
  • Keywords
    gas mixtures; position sensitive particle detectors; proportional counters; radiation hardening; Ar; DME; MICROMEGAS detector; Ne; cyclohexane; gain maximum; gas mixtures; gaseous detector; high rate results; isobutane; quencher; radiation hardness results; tetrafluoromethane; Copper; Current measurement; Electrodes; Gain measurement; Particle beams; Spatial resolution; Strips; Testing; X-ray detection; X-ray detectors;