DocumentCode :
340703
Title :
An aging study of a gas electron multiplier detector with microstrip gas chamber readout
Author :
Miyamoto, J. ; Shipsey, I.P.J.
Author_Institution :
Dept. of Phys., Purdue Univ., West Lafayette, IN, USA
Volume :
1
fYear :
1998
fDate :
1998
Firstpage :
598
Abstract :
The aging behavior of wire chambers have been of great interest for many years. Recently a new generation of proportional chambers have been developed including the microstrip gas chamber (MSGC) microgap chamber (MGC) and gaseous electron multiplier (GEM). Aging studies of these detectors are of particular interest to the LHC (Large Hadron Collider) community because the baseline design of the CMS experiment includes MSGCs as part of the tracking system. We have performed an aging study of a GEM detector readout with a MSGC
Keywords :
ageing; electron multiplier detectors; position sensitive particle detectors; proportional counters; GEM; MGC; MSGC; aging study; gas electron multiplier detector; microgap chamber; microstrip gas chamber readout; proportional chambers; wire chambers; Aging; Collision mitigation; Copper; Detectors; Electron multipliers; Energy resolution; Large Hadron Collider; Microstrip; Microstructure; Wire;