DocumentCode
3410446
Title
Monitoring charging in high current ion implanters yields optimum preventive maintenance schedules and procedures
Author
Gonzalez, Henry ; Reno, Steve ; Messick, Cleston ; Lukaszek, Wes ; Romanski, Thomas
Author_Institution
Fairchild Semicond., West Jordan, UT, USA
Volume
1
fYear
1999
fDate
1999
Firstpage
554
Abstract
Gate to substrate charging during high current ion implantation correlates to gate oxide damage seen at product testing or during reliability assessment, as can be discovered by tedious statistical evaluations. However, variations in charging over time do not lend themselves to the same statistical analysis. Using CHARM(R)-2 to proactively monitor charging on a consistent basis over 12 months detected adverse trends before charging levels impacted yield or reliability. Variations in charging levels also correlated to preventive maintenance schedules, indicating a need to implement optimum timing and procedures. Trends for different implanters demonstrate the results of successfully implementing procedural changes, which reduced peak charging potentials and minimized equipment drift
Keywords
ion implantation; semiconductor device manufacture; semiconductor device reliability; semiconductor doping; CHARM(R)-2; charging; gate oxide damage; gate to substrate charging; high current ion implanters; minimized equipment drift; optimum preventive maintenance schedules; proactively monitor charging; product testing; reduced peak charging potentials; reliability; reliability assessment; yield; Dielectric losses; Monitoring; Plasma immersion ion implantation; Plasma materials processing; Plasma measurements; Preventive maintenance; Scheduling; Substrates; Testing; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Ion Implantation Technology Proceedings, 1998 International Conference on
Conference_Location
Kyoto
Print_ISBN
0-7803-4538-X
Type
conf
DOI
10.1109/IIT.1999.812176
Filename
812176