DocumentCode :
3412184
Title :
Migrated copper resistive shorts in plastic encapsulated devices
Author :
Yalamanchili, P. ; Christou, Alex
Author_Institution :
Dept. of Mater. & Nucl. Eng., Maryland Univ., College Park, MD, USA
fYear :
1995
fDate :
22-25 Oct. 1995
Firstpage :
166
Abstract :
Summary form only given. Integrated-circuit devices using the Al-Cu bond pad systems may be subjected to failure mechanisms based on electrolytic corrosion. The migratory copper resistive short (MCRS) failure mode is one example of this mechanism and results in the formation of filamentary or dendritic deposits of copper between adjacent bond pads on the IC chip. Such a failure mode was identified in the plastic encapsulated ECL devices. A number of advanced analytical techniques have been applied in order to characterize the failure mechanism. These techniques included environmental scanning electron microscopy (ESEM), energy dispersive X-ray spectroscopy (EDX) and c-mode scanning acoustic microscopy (C-SAM). A model, based on the physics of condensation, ionic migration and thermally activated mechanism, was developed, and verified with the field returned failure data. The source of moisture, copper and ionic contaminants that accelerate the failure mechanism were also discussed.
Keywords :
X-ray chemical analysis; acoustic microscopy; aluminium alloys; copper alloys; corrosion; electromigration; emitter-coupled logic; encapsulation; failure analysis; integrated circuit metallisation; integrated circuit packaging; integrated circuit reliability; plastic packaging; reliability theory; scanning electron microscopy; Al-Cu bond pad systems; AlSiCu; C-SAM; EDX; IC chip; analytical techniques; c-mode scanning acoustic microscopy; condensation physics; dendritic deposits; electrolytic corrosion; energy dispersive X-ray spectroscopy; environmental scanning electron microscopy; failure mechanism acceleration; failure mechanisms; field returned failure data; filamentary deposits; ionic contaminants; ionic migration; migrated Cu resistive short failure mode; model; plastic encapsulated ECL devices; thermally activated mechanism; Acoustic devices; Bonding; Copper; Corrosion; Dispersion; Failure analysis; Physics; Plastics; Scanning electron microscopy; Spectroscopy;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Integrated Reliability Workshop, 1995. Final Report., International
Conference_Location :
Lake Tahoe, CA, USA
Print_ISBN :
0-7803-2705-5
Type :
conf
DOI :
10.1109/IRWS.1995.493603
Filename :
493603
Link To Document :
بازگشت