DocumentCode
3425970
Title
AC analysis of Dc/DC resonant converters
Author
Caliskan, Vahé A. ; Liu, Rui ; Lee, C.Q.
Author_Institution
Illinois Univ., Chicago, IL, USA
fYear
1992
fDate
29 Jun-3 Jul 1992
Firstpage
354
Abstract
The authors introduce some extensions to R.L. Steigenwald´s (1988) classical AC analysis of resonant DC/DC power converters. These include applications to third-order systems and one class of zero voltage switching (ZVS) converters. Based on analog filter theory, one can explain why the third-order counterparts of the series resonant converter and parallel resonant converter possess improved characteristics. Gain sensitivity is introduced as a performance index for comparing performance characteristic features. It is shown that at least one other class of ZVS converter can be analyzed by using an extension to this approach
Keywords
network analysis; power convertors; switching circuits; ZVS; analog filter theory; applications; classical AC analysis; gain sensitivity; network analysis; performance index; resonant DC/DC power converters; third-order systems; zero voltage switching; Analog-digital conversion; Filtering theory; Filters; Laboratories; Partial response channels; Performance gain; RLC circuits; Resonance; Topology; Zero voltage switching;