DocumentCode
3426689
Title
Evaluating stray current from DC electrified transit systems with lumped parameter and multi-layer soil models
Author
Fichera, F. ; Mariscotti, A. ; Ogunsola, A.
Author_Institution
DITEN, Univ. of Genova, Genoa, Italy
fYear
2013
fDate
1-4 July 2013
Firstpage
1187
Lastpage
1192
Abstract
DC electrified traction systems are a potential source of stray current, that may corrode both internal and external structures and installations. The stray current intensity depends on several factors (traction current, rail insulation, concrete mat and piers resistance), that are accounted for in the proposed model. Moreover, the effect of a uniform or multi-layer soil model is considered, showing the differences and the impact on the countermeasures with respect to a uniform soil model simplifying approach.
Keywords
corrosion; earthing; leakage currents; railway electrification; soil; traction power supplies; DC electrified traction system; DC electrified transit system; concrete mat; external structure corrosion; internal structure corrosion; lumped parameter; multilayer soil model; piers resistance; rail insulation; stray current; traction current; Concrete; Conductivity; Electric potential; Integrated circuit modeling; Rails; Resistance; Soil; Corrosion; Electromagnetic conductive interference; Guideway transportation power systems; Power distribution electromagnetic interference; Stray current;