DocumentCode
3428089
Title
Power feed-back during controller failure in inverter fed permanent magnet synchronous motor drives with flux weakening
Author
Adnanes, Alf Kare ; Nilssen, Robert ; Rad, Rolf Ove
Author_Institution
ABB Corp. Res., Billingstad, Norway
fYear
1992
fDate
29 Jun-3 Jul 1992
Firstpage
958
Abstract
When permanent magnet synchronous motors are operated in the flux weakening region, the internal voltage can be much larger than the DC link voltage. If the switching signals are blocked, the freewheeling diodes act as a rectifier, and the motor will feed power back into the inverter. The magnitude of the feedback power during such controller failure is investigated. Simulations and approximate analyses are used to obtain descriptive and comparative curves. Measurements verify the computer results but also show that nonlinear effects could have significant influence
Keywords
electric drives; feedback; invertors; machine control; magnetic flux; permanent magnet motors; synchronous motors; controller failure; flux weakening; freewheeling diodes; inverter fed permanent magnet synchronous motor drives; nonlinear effects; power feedback; rectifier; Analytical models; Computational modeling; Diodes; Feedback; Feeds; Inverters; Permanent magnet motors; Rectifiers; Synchronous motors; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics Specialists Conference, 1992. PESC '92 Record., 23rd Annual IEEE
Conference_Location
Toledo
Print_ISBN
0-7803-0695-3
Type
conf
DOI
10.1109/PESC.1992.254780
Filename
254780
Link To Document