Abstract :
This paper examines a synchronous rectification of a forward converter that uses a constant-current circuit for the transformer reset. To reduce loss in the constant-current circuit, the converter is connected to supply some of the power to the load. The question of optimizing the reset power is considered and the power distribution is shown. The reset power was set to its optimum value, and experimental values were used to examine this. We also investigated operations under no-load and show that the converter operates normally and that the reset is being performed
Keywords :
DC-DC power convertors; losses; power MOSFET; rectification; transformers; MOSFET synchronous rectification; constant current transformer reset circuit; constant-current circuit; forward converter; loss reduction; no-load operation; power distribution; reset power optimisation; transformer reset; Current transformers; Diodes; Equations; Large scale integration; MOSFETs; Power distribution; Snubbers; Switches; Switching circuits; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics Specialists Conference, 1998. PESC 98 Record. 29th Annual IEEE
Conference_Location :
Fukuoka
ISSN :
0275-9306
Print_ISBN :
0-7803-4489-8
Type :
conf
DOI :
10.1109/PESC.1998.703161
Filename :
703161
Link To Document :
بازگشت