DocumentCode :
3441288
Title :
Determination of the Accumulated Location of Microparticle Collection Caused by AC EO
Author :
Yang, Hukun ; Jiang, Hongyuan ; Yan, Hui ; Ma, Changbo
Author_Institution :
Harbin Inst. of Technol., Harbin
fYear :
2007
fDate :
23-25 May 2007
Firstpage :
251
Lastpage :
254
Abstract :
AC electroosmosis (AC EO) shows many advantages in collecting microparticles, such as low signal voltage, little sample, real-time detection and integrating in microchip easily. An experiment showed that the microparticles in sample would be accumulated on a fixed field on the surface of the microelectrodes caused by the AC electric field. Based on the phenomena, the velocity field of AC EO in microchannel is explored and the process of microparticles accumulated is explained. The location of microparticles accumulated is determined based on the numerical simulation results, at the same time, the rate relation between the accumulated location and the width of microelectrode, which offers the theoretic base for further analyzing and detecting microparticles.
Keywords :
electric fields; electrokinetic effects; electrophoresis; microelectrodes; AC EO; AC electric field; AC electroosmosis; accumulated location; microelectrode surface; microparticle collection; Industrial electronics;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Electronics and Applications, 2007. ICIEA 2007. 2nd IEEE Conference on
Conference_Location :
Harbin
Print_ISBN :
978-1-4244-0737-8
Electronic_ISBN :
978-1-4244-0737-8
Type :
conf
DOI :
10.1109/ICIEA.2007.4318409
Filename :
4318409
Link To Document :
بازگشت