DocumentCode
3442084
Title
Small wind turbine generator monitoring: A test facility and preliminary analysis
Author
Hongwei Cai ; Wood, David ; Qiao Sun
Author_Institution
Dept. of Mech. & Manuf. Eng., Univ. of Calgary, Calgary, AB, Canada
fYear
2013
fDate
15-18 July 2013
Firstpage
1698
Lastpage
1701
Abstract
In order to simulate wind turbine generators working at variable speed and develop new condition monitoring and fault diagnosis techniques, a test facility based on a 500 W permanent magnet generator was built. Mechanical faults in the ball bearing outer race and rotor imbalance were simulated. Three vibration analysis techniques were performed and compared. Order analysis proved to be a simple, intuitive and reliable technique for vibration analysis under variable speed.
Keywords
ball bearings; condition monitoring; fault diagnosis; permanent magnet generators; power generation reliability; rotors; vibrations; wind turbines; ball bearing outer race; condition monitoring; fault diagnosis technique; mechanical faults; permanent magnet generator; preliminary analysis; rotor imbalance; small-wind turbine generator monitoring; test facility; vibration analysis technique; wind turbine generator simulation; Accelerometers; Condition monitoring; Continuous wavelet transforms; Generators; Test facilities; Vibrations; Wind turbines; condition monitoring; order analysis; small wind turbine generator; test facility; time-frequency analysis; vibration analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Quality, Reliability, Risk, Maintenance, and Safety Engineering (QR2MSE), 2013 International Conference on
Conference_Location
Chengdu
Print_ISBN
978-1-4799-1014-4
Type
conf
DOI
10.1109/QR2MSE.2013.6625903
Filename
6625903
Link To Document