Abstract :
A susceptibility test of devices exposed to the electromagnetic environment of the system requires 20 dB safety margins. In order to verify these there are several test methods based on measuring the RF current. flowing through the EED. The involvement of the measuring sensor in the EED´s circuit causes problems of electromagnetic energy penetration through the sensor´s wires and thus the accuracy of the current measurement is degraded. The suggested test method eliminates this problem by replacing the EED with a fuse. If the fuse is not blown during the test, it is understood that the maximum current is less then indicated by the fuse data sheet, and this current is used in evaluation of the safety margins
Keywords :
electric current measurement; electric fuses; electromagnetic compatibility; electron device testing; military standards; safety; MIL-E-6051D; RF current; accuracy; electro-explosive devices; electromagnetic energy penetration; fuse; safety margins; susceptibility test; test method; Circuit testing; Current measurement; Electromagnetic devices; Electromagnetic measurements; Energy measurement; Fuses; Radio frequency; Safety devices; System testing; Wires;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility, 1992. From a Unified Region to a Unified World., 1992 Regional Symposium on
Conference_Location :
Tel-Aviv
Print_ISBN :
0-7803-0725-9
Type :
conf
DOI :
10.1109/ISEMC.1992.257559
Filename :
257559
Link To Document :
بازگشت