    LCL-filter design for grid-connected PCS using total harmonic distortion and ripple attenuation factor

  • Author

    Park, Min-Young ; Chi, Min-Hun ; Park, Jong-Hyoung ; Kim, Heung-Geun ; Chun, Tae-Won ; Nho, Eui-Cheol

  • Author_Institution
    Kyungpook Nat. Univ., Daegu, South Korea
  • fYear
    2010
  • fDate
    21-24 June 2010
  • Firstpage
    1688
  • Lastpage
    1694
  • Abstract
    This paper deals with a design method of LCL filter for grid-connected three-phase PWM voltage source inverters (VSI). By analyzing the total harmonic distortion of the current (THDi) in the inverter-side inductor and the ripple attenuation factor of the current (RAF) injected to the grid through the LCL network, the parameter of LCL can be clearly designed. The described LCL filter design method is verified by showing a good agreement between the target current THD and the actual one through simulation and experiment.
  • Keywords
    PWM invertors; harmonic distortion; power filters; power grids; power inductors; LCL filter design method; grid-connected PCS; grid-connected power conditioning system; grid-connected three-phase PWM voltage source inverters; inverter-side inductor; ripple attenuation factor; total harmonic distortion analysis; Attenuation; Design methodology; Inductors; Low pass filters; Personal communication networks; Power harmonic filters; Pulse width modulation; Pulse width modulation inverters; Total harmonic distortion; Voltage; LCL-filter design; grid-connected inverter; ripple attenuation factor; total harmonic distortion;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Conference (IPEC), 2010 International
  • Conference_Location
    Sapporo
  • Print_ISBN
    978-1-4244-5394-8
  • Type

    conf

  • DOI
    10.1109/IPEC.2010.5542131
  • Filename
    5542131