Abstract :
This paper deals with a design method of LCL filter for grid-connected three-phase PWM voltage source inverters (VSI). By analyzing the total harmonic distortion of the current (THDi) in the inverter-side inductor and the ripple attenuation factor of the current (RAF) injected to the grid through the LCL network, the parameter of LCL can be clearly designed. The described LCL filter design method is verified by showing a good agreement between the target current THD and the actual one through simulation and experiment.
Keywords :
PWM invertors; harmonic distortion; power filters; power grids; power inductors; LCL filter design method; grid-connected PCS; grid-connected power conditioning system; grid-connected three-phase PWM voltage source inverters; inverter-side inductor; ripple attenuation factor; total harmonic distortion analysis; Attenuation; Design methodology; Inductors; Low pass filters; Personal communication networks; Power harmonic filters; Pulse width modulation; Pulse width modulation inverters; Total harmonic distortion; Voltage; LCL-filter design; grid-connected inverter; ripple attenuation factor; total harmonic distortion;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics Conference (IPEC), 2010 International
Conference_Location :
Sapporo
Print_ISBN :
978-1-4244-5394-8
Type :
conf
DOI :
10.1109/IPEC.2010.5542131
Filename :
5542131
Link To Document :
بازگشت