Title :
Effect of re-radiated emission from power cord
Author_Institution :
Yokogawa-Hewlett-Packard Ltd., Tokyo
Abstract :
Radiation emission from a product with an AC power cord can be larger than from a product without an AC power cord between 30 and 200 MHz. This indirect RF current induced from a RF source of another outer antenna is different for AC power cord arrangements and earthing methods. This paper reports sample data and assumed cause of power cord effects
Keywords :
earthing; radiofrequency interference; wiring; 30 to 200 MHz; AC power cord; VHF; earthing methods; indirect RF current; power cord effects; re-radiated emission; Cable shielding; Conductors; Contact resistance; FCC; Power system protection; Predictive models; Surface impedance; Surface resistance; Telecommunications; Wires;
Conference_Titel :
Electromagnetic Compatibility, 1992. From a Unified Region to a Unified World., 1992 Regional Symposium on
Conference_Location :
Tel-Aviv
Print_ISBN :
0-7803-0725-9
DOI :
10.1109/ISEMC.1992.257597