    Allan Variances for DC Voltage Measurements with Polarity Reversals

  • Author

    Witt, Thomas J.

  • Author_Institution
    Bur. Int. des Poids et Mesures (BIPM), Sevres
  • fYear
    2004
  • fDate
    38139
  • Firstpage
    64
  • Lastpage
    65
  • Abstract
    Precise measurements of dc voltage were made using a polarity reversal technique and the results were analyzed using the Allan variance. These were then compared with the Allan variances for unreversed or unipolar measurements of the same processes. The Allan variances were found to agree quite well, particularly for sampling times corresponding to the 1/f noise regime for the measurement of Zener-diode voltages
  • Keywords
    1/f noise; Zener diodes; voltage measurement; 1/f noise; Allan variances; Zener-diode voltages; dc voltage measurements; polarity reversal technique; polarity reversals; unipolar measurements; Analysis of variance; Circuit testing; Low pass filters; Noise measurement; Particle measurements; Sampling methods; Switches; Voltage measurement; Voltmeters; White noise;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2004 Conference on
  • Conference_Location
    London
  • Print_ISBN
    0-7803-8494-6
  • Electronic_ISBN
    0-7803-8494-6
  • Type

    conf

  • DOI
    10.1109/CPEM.2004.305442
  • Filename
    4097116