DocumentCode :
344463
Title :
The electron accelerator installations with local shielding for applied purposes
Author :
Batskikh, G. ; Mamaev, G. ; Mischenko, A. ; Pirozhenko, V.
Author_Institution :
MRTI, Acad. of Sci., Moscow, Russia
Volume :
4
fYear :
1999
fDate :
1999
Firstpage :
2564
Abstract :
The use of the local shielding for electron accelerators considerably extends the capabilities of its application for various purposes, because they can operate in ordinary working rooms. So there is no need to construct special buildings with cumbersome shielding. Since the cost of local shielding depends on its sizes, the compact accelerators have developed in the MRTI. Three accelerating installations are presented in the report: 8 MeV installation for custom inspection of large cargo containers, 5 MeV installation for sterilization of medical instruments, infectious waste, conservation food etc., and 200 keV installation for industrial techniques
Keywords :
biomedical equipment; electron accelerators; inspection; linear accelerators; security; shielding; 200 keV; 5 MeV; 8 MeV; compact linear accelerators; custom inspection; electron accelerator installations; infectious waste; large cargo containers; linac; local shielding; medical instruments; sterilization; Acceleration; Biomedical imaging; Buildings; Containers; Electron accelerators; Electron beams; Inspection; Instruments; Linear particle accelerator; Pulse transformers;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1999. Proceedings of the 1999
Conference_Location :
New York, NY
Print_ISBN :
0-7803-5573-3
Type :
conf
DOI :
10.1109/PAC.1999.792777
Filename :
792777
Link To Document :
بازگشت