• DocumentCode
    3444699
  • Title

    Frequency Dependence of the Dissipation Factor of Capacitors up to 10 KHZ

  • Author

    Eklund, G.

  • Author_Institution
    SP Swedish Nat. Testing & Res. Inst.,, Boris
  • fYear
    2004
  • fDate
    38139
  • Firstpage
    95
  • Lastpage
    96
  • Abstract
    The frequency dependence of the dissipation factor for two types of capacitance standards have been determined with the use of a parallel plate capacitor. The absolute measurements of dissipation factor have been performed at 1 kHz, 4 kHz and 10 kHz
  • Keywords
    capacitance measurement; capacitors; measurement standards; 1 kHz; 10 kHz; 4 kHz; capacitance standards; capacitor dissipation factor; frequency dependence; parallel plate capacitor; Bridge circuits; Calibration; Capacitance measurement; Capacitors; Error correction; Frequency dependence; Instruments; Performance evaluation; Stability; Uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2004 Conference on
  • Conference_Location
    London
  • Print_ISBN
    0-7803-8494-6
  • Electronic_ISBN
    0-7803-8494-6
  • Type

    conf

  • DOI
    10.1109/CPEM.2004.305458
  • Filename