Title :
Frequency Dependence of the Dissipation Factor of Capacitors up to 10 KHZ
Author_Institution :
SP Swedish Nat. Testing & Res. Inst.,, Boris
Abstract :
The frequency dependence of the dissipation factor for two types of capacitance standards have been determined with the use of a parallel plate capacitor. The absolute measurements of dissipation factor have been performed at 1 kHz, 4 kHz and 10 kHz
Keywords :
capacitance measurement; capacitors; measurement standards; 1 kHz; 10 kHz; 4 kHz; capacitance standards; capacitor dissipation factor; frequency dependence; parallel plate capacitor; Bridge circuits; Calibration; Capacitance measurement; Capacitors; Error correction; Frequency dependence; Instruments; Performance evaluation; Stability; Uncertainty;
Conference_Titel :
Precision Electromagnetic Measurements Digest, 2004 Conference on
Conference_Location :
London
Print_ISBN :
0-7803-8494-6
Electronic_ISBN :
0-7803-8494-6
DOI :
10.1109/CPEM.2004.305458