• DocumentCode
    3445538
  • Title

    Defect estimation of a crack in underground pipelines by CMFL type NDT system

  • Author

    Hui Min Kim ; Yong Woo Rho ; Hui Ryong Yoo ; Sung Ho Cho ; Dong Kyu Kim ; Sung Ja Koo ; Gwan Soo Park

  • Author_Institution
    Dept. of Electr. Eng., Pusan Nat. Univ., Pusan, South Korea
  • fYear
    2013
  • fDate
    26-29 Oct. 2013
  • Firstpage
    725
  • Lastpage
    728
  • Abstract
    A defect which is axially oriented with small size is hard to detect in conventional system. CMFL (Circumferential Magnetic Flux Leakage) type PIG (Pipelines Inspection Gauge) in the NDT (Nondestructive Testing), is operated to detect this defect called axially oriented cracks in the pipe. It is necessary to decompose the size and shapes of cracks for the maintenance of underground pipelines. This article is focused on the decomposing method of the size and shape of the axially oriented cracks by using inspection signal data for defect.
  • Keywords
    crack detection; inspection; magnetic flux; magnetic leakage; pipelines; CMFL; NDT system; axially oriented crack shape decomposing method; axially oriented crack size decomposing method; circumferential magnetic flux leakage; crack defect estimation; inspection signal data; nondestructive testing; pipelines inspection gauge; underground pipelines; Estimation; Magnetic flux leakage; Magnetometers; Pipelines; Saturation magnetization; Sensors; Shape;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines and Systems (ICEMS), 2013 International Conference on
  • Conference_Location
    Busan
  • Print_ISBN
    978-1-4799-1446-3
  • Type

    conf

  • DOI
    10.1109/ICEMS.2013.6754511
  • Filename
    6754511