Abstract :
This paper presents two low voltage ac-dc difference measurement systems established at SPRING Singapore. The systems use micropotentiometers and resistive divider to scale the voltage from primary reference level to 1 mV to provide accurate mV-level ac-dc difference calibration at frequency range from 10 Hz to 1 MHz. The measurement results of the two systems and the loading effect correction are discussed
Keywords :
calibration; measurement standards; potentiometers; voltage measurement; 10 to 1000000 Hz; SPRING Singapore; loading effect correction; low voltage AC-DC difference standards; micropotentiometers; resistive divider; Calibration; Flowcharts; Frequency; Low voltage; Measurement standards; Metrology; Springs; Standards development; Switches; Voltage measurement;