• DocumentCode
    344575
  • Title

    Analytical studies of top-up safety for the Advanced Photon Source

  • Author

    Emery, L. ; Borland, M.

  • Author_Institution
    Argonne Nat. Lab., IL, USA
  • Volume
    4
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    2939
  • Abstract
    The Advanced Photon Source (APS) is a 7 GeV, third-generation synchrotron radiation source. To provide more stable beam for users, we are pursuing a new operating mode called “top-up.” In this mode, the beam current is not allowed to decay as it normally would, but instead is maintained at a high level through frequent injection. A safety question with top-up mode is, during injection with photon shutters open, can the injected beam ever exit a photon beamline? This might happen, for example, due to a full or partial short of a dipole coil. We discuss a number of analytical calculations that can be used to quickly assess top-up safety for a general ring. We also apply these results to the specific case of the APS. A companion paper in this conference discusses detailed tracking procedures for assessing safety
  • Keywords
    electron accelerators; particle beam injection; safety; storage rings; synchrotrons; APS; Advanced Photon Source; injection; operating mode; safety; top-up; Apertures; Coils; Lattices; Particle beam injection; Protection; Radiation safety; Storage rings; Sufficient conditions; Synchrotron radiation; Voltage fluctuations;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1999. Proceedings of the 1999
  • Conference_Location
    New York, NY
  • Print_ISBN
    0-7803-5573-3
  • Type

    conf

  • DOI
    10.1109/PAC.1999.792989
  • Filename
    792989