DocumentCode
3446227
Title
APMP International Comparison of AC-DC Transfer Standards at the Lowest Attainable Level of Uncertainty
Author
Budovsky, Ilya ; Abdul Rashid Bin Zainal Abidin ; Yan, Y.K. ; Lingxiang, Liu ; Rustagi, V.K. ; Govil, A.K. ; Klonz, Manfred ; Wei, Yih-cheng ; Early, Murray ; Sasaki, Hitoshi ; Fujiki, Hiroyuki ; Kumtawee, Chalit ; Kwon, Sung-Won ; Son, Nguyen Anh ; Supri
Author_Institution
Nat. Meas. Lab., Lindfield, NSW
fYear
2004
fDate
38139
Firstpage
250
Lastpage
251
Abstract
The paper presents preliminary results of the APMP.EM-K6a key comparison of ac-dc transfer conducted during 2000-2003. The ac-dc voltage transfer difference of the travelling standard was measured at 3 V and selected frequencies from 1 kHz to 1 MHz that included those of the CCEM-K6a key comparison. Also discussed are the methods used to compare TVCs with different input connectors, and to link the results to the parent CCEM comparison
Keywords
measurement uncertainty; transfer standards; voltage measurement; 0.001 to 1 MHz; 3 V; APMP international comparison; APMP.EM-K6a key comparison; TVC; ac-dc voltage transfer transfer standards; input connectors; Australia; Bars; Connectors; Current measurement; Laboratories; Metrology; Springs; Thermal resistance; Uncertainty; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 2004 Conference on
Conference_Location
London
Print_ISBN
0-7803-8494-6
Electronic_ISBN
0-7803-8494-6
Type
conf
DOI
10.1109/CPEM.2004.305556
Filename
4097211