• DocumentCode
    3446250
  • Title

    Comparison Euromet.EM-K8 of DC Voltage Ratio: Results

  • Author

    Marullo-Reedtz, G. ; Cerri, R. ; Waldmann, W. ; Streit, J. ; Immonen, P. ; Blanc, I. ; Raso, F. ; Funck, T. ; Schumacher, B. ; Dierikx, E. ; Nunes, M. ; Vrabcek, P. ; Rudohradsky, D. ; Gunnarsson, O. ; Jeanneret, B. ; Jeckelmann, B. ; Pulfer, T. ; Turhan,

  • Author_Institution
    Ist. Elettrotecnico Nazionale, Torino
  • fYear
    2004
  • fDate
    38139
  • Firstpage
    252
  • Lastpage
    253
  • Abstract
    Twenty National Metrology Institutes have participated in the European DC voltage ratio key comparison (EUROMET.EM-K8). The results for the voltage ratios 1000V/10V and 100V/10V are reported
  • Keywords
    voltage measurement; 10 V; 100 V; 1000 V; EUROMET.EM-K8; European DC voltage ratio key comparison; National Metrology Institutes; Battery powered vehicles; Humidity; Interpolation; Laboratories; Measurement standards; Measurement uncertainty; Metrology; Particle measurements; Temperature; Voltage measurement;