• DocumentCode
    3447060
  • Title

    Fast resistive attenuators for high accuracy measurements of LI voltages

  • Author

    Chekurov, Yuri Y. ; Hällström, Jari K.

  • Author_Institution
    High Voltage Inst., Helsinki Univ. of Technol.
  • fYear
    2004
  • fDate
    38139
  • Firstpage
    328
  • Lastpage
    329
  • Abstract
    Design, construction and calibration of compact, inexpensive and fast resistive attenuators for lightning impulse or surge voltage measurements up to 1.5 kV is presented. Estimated uncertainty of attenuator ratio is less than 100 ppm (k=2). The input resistance of attenuators is 50 Omega plusmn 1 % and the rise-time is less than 1 ns. The calibration procedure of the attenuators is described
  • Keywords
    attenuators; calibration; measurement uncertainty; surges; voltage measurement; calibration; lightning impulses voltages measurement; lightning surge voltage measurement; uncertainty; Attenuation measurement; Attenuators; Calibration; Flanges; Immune system; Lightning; Resistors; Stability; Testing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2004 Conference on
  • Conference_Location
    London
  • Print_ISBN
    0-7803-8494-6
  • Electronic_ISBN
    0-7803-8494-6
  • Type

    conf

  • DOI
    10.1109/CPEM.2004.305598
  • Filename
    4097253