• DocumentCode
    3447071
  • Title

    Suppressing of common mode voltage on ac motor with changing ground point of DC link in PWM inverter

  • Author

    Iimori, K. ; Yamamoto, K. ; Jyosui, S.

  • Author_Institution
    Grad. Sch. of Electr. & Electron. Eng., Kagoshima Univ., Kagoshima, Japan
  • fYear
    2010
  • fDate
    21-24 June 2010
  • Firstpage
    2488
  • Lastpage
    2492
  • Abstract
    With the increased application of adjustable-speed drive of AC motor, there has been a growing number of failures such as electromagnetic interference(EMI) caused by common mode current, and bearing current. Especially, bearing current leads to motor bearing material erosion and early mechanical failure. To reduce the bearing current, there are two methods, one is reduce the common mode voltage, and another one is reduce the motor shaft voltage itself. This paper describes the approaches to suppress the Common mode voltage on ac motor with changing the ground point of DC link in PWM inverter.
  • Keywords
    AC motor drives; PWM invertors; variable speed drives; AC motor; DC link ground point; PWM inverter; adjustable-speed drive; bearing current; common mode current; common mode voltage suppression; electromagnetic interference; mechanical failure; motor bearing material erosion; motor shaft voltage; AC motors; Detectors; Pulse circuits; Pulse generation; Pulse inverters; Pulse width modulation inverters; Shafts; Switches; Switching circuits; Voltage; bearing current; common mode voltage; ground point changing; shaft voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Conference (IPEC), 2010 International
  • Conference_Location
    Sapporo
  • Print_ISBN
    978-1-4244-5394-8
  • Type

    conf

  • DOI
    10.1109/IPEC.2010.5542374
  • Filename
    5542374