DocumentCode :
3447389
Title :
An Algorithm for Accurately Estimating the Harmonic Magnitudes of Periodic Arbitrary Signals using Asynchronous Sampling
Author :
Kyriazis, G.A.
Author_Institution :
Instituto Nat. de Metrologia, Normalizacilo e Qualidade Ind., Rio de Janiero
fYear :
2004
fDate :
38139
Firstpage :
358
Lastpage :
359
Abstract :
An algorithm that uses an integrating voltmeter for accurately estimating the harmonic magnitudes of periodic arbitrary signals is presented. The uncertainties associated with the magnitude estimates relative to the fundamental depend on signal stability, harmonic content, noise variance and are less than 1 times 10-5 for signals with up to 64 harmonics
Keywords :
estimation theory; measurement uncertainty; voltmeters; asynchronous sampling; harmonic content; harmonic magnitudes; integrating voltmeter; noise variance; periodic arbitrary signals; signal stability; Covariance matrix; Discrete Fourier transforms; Error correction; Frequency estimation; Frequency response; Sampling methods; Signal generators; Signal synthesis; Voltage; Voltmeters;
fLanguage :
English