Title :
Origins of high voltage continuity failures in enamel coated copper magnet wire
Author :
Pops, Horace ; Walker, Julie
Author_Institution :
Essex Group, Inc., Fort Wayne, IN, USA
Abstract :
Continuity testing of film insulated copper magnet wire is conducted under high-voltage AC conditions to determine the exact causes of electrical failures. A special apparatus is built to pinpoint the precise location of such defects. Using visual examination, metallographic evaluation of cross-sections, scanning electron microscopy (SEM) examination of the bare wire surfaces, and elemental analysis of foreign contaminants, the genus of continuity faults is categorized, and is broken down into six different major classifications. A comparison between beady wire and continuity failures is presented
Keywords :
insulated wires; AC conditions; Cu; SEM; bare wire surfaces; beady wire; contaminants analysis; defect location; electrical failures; enamel coated copper magnet wire; high voltage continuity failures; metallographic evaluation; scanning electron microscopy; visual examination; Cable insulation; Conductive films; Copper; Dielectrics and electrical insulation; Magnetic analysis; Scanning electron microscopy; Surface contamination; Testing; Voltage; Wire;
Conference_Titel :
Electrical Electronics Insulation Conference and Electrical Manufacturing & Coil Winding Conference, 1993. Proceedings., Chicago '93 EEIC/ICWA Exposition
Conference_Location :
Chicago, IL
Print_ISBN :
0-7803-0847-6
DOI :
10.1109/EEIC.1993.631223