DocumentCode :
3447668
Title :
Compatibility of nonmetallic motor components with R22 and R502 replacement refrigerants
Author :
Corr, S. ; Dekleva, T.W. ; Dowdle, P. ; Tompsett, G. ; Allison, J. ; Brutsch, R.
Author_Institution :
ICI Klea, Widnes, Cheshire, UK
fYear :
1993
fDate :
4-7 Oct 1993
Firstpage :
507
Lastpage :
511
Abstract :
A range of hermetic compressor motor insulation materials is examined for compatibility with the hydrofluorocarbon (HFC) refrigerants HFC32, HFC134a and HFC125 and with a neopentylpolyol ester refrigeration lubricant. The results indicate that when compared to R22 and R22-mineral oil standards, the HFC refrigerants and the refrigerant-lubricant mixtures show comparable, or in many cases less aggressive, behavior towards the majority of the motor insulation materials studied
Keywords :
refrigeration; HFC125; HFC134a; HFC32; R22; R502; hermetic compressor motor insulation; hydrofluorocarbon refrigerants; neopentylpolyol ester refrigeration lubricant; nonmetallic motor components; Air conditioning; Automotive engineering; Dielectrics and electrical insulation; Hybrid fiber coaxial cables; Lubricants; Petroleum; Phase measurement; Protocols; Refrigerants; Refrigeration;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Electronics Insulation Conference and Electrical Manufacturing & Coil Winding Conference, 1993. Proceedings., Chicago '93 EEIC/ICWA Exposition
Conference_Location :
Chicago, IL
ISSN :
1071-6270
Print_ISBN :
0-7803-0847-6
Type :
conf
DOI :
10.1109/EEIC.1993.631246
Filename :
631246
Link To Document :
بازگشت