DocumentCode :
3447673
Title :
HEMP performance assessment of an AT&T 4 ESS digital switch
Author :
Olszewski, C.J. ; Duerksen, G.L. ; Spata, D.A.
Author_Institution :
AT&T Bell Labs., Holmdel, NJ, USA
fYear :
1991
fDate :
4-7 Nov 1991
Firstpage :
755
Abstract :
AT&T has conducted a test program to assess the performance of the largest switch in AT&T´s network, the AT&T 4 ESS switch, when subjected to the effects of high-altitude electromagnetic pulse (HEMP). The methodology and results of these tests are presented. In this test program, the switch under test was surrounded by as little external electromagnetic shielding as possible
Keywords :
electromagnetic pulse; electronic switching systems; 4 ESS digital switch; AT&T; HEMP performance assessment; high-altitude electromagnetic pulse; test program; Central office; Circuits; Communication system signaling; Degradation; Electromagnetic compatibility; Electronic switching systems; ISDN; Surges; Switches; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Military Communications Conference, 1991. MILCOM '91, Conference Record, Military Communications in a Changing World., IEEE
Conference_Location :
McLean, VA
Print_ISBN :
0-87942-691-8