Abstract :
We have studied the accuracy of the atomic microwave power standard. The atoms are cooled and kept in a magneto-optical trap (MOT), then dropped through a terminated transmission line (a rectangular, R-70 type, waveguide). The measurement of the internal atomic state allows an accurate determination of the transmitted microwave power
Keywords :
magnetic traps; magneto-optical effects; measurement standards; microwave measurement; microwave power transmission; power measurement; R-70 type waveguide; atomic microwave power standard; internal atomic state; magneto-optical trap; terminated transmission line; Atomic beams; Atomic measurements; Detectors; Electromagnetic waveguides; Magnetic field measurement; Measurement standards; Power measurement; Power transmission lines; Rectangular waveguides; Transmission line measurements;