Abstract
Connecting thermal current converters (TCC) in series for calibration of current ac-dc difference, attention has to be paid to the various current leakages that may occur. Calculations indicate leakage error less than 2*10-6 at frequencies up to 100 kHz. Measured values show that error contributions are less than 1*10-6 at 100 kHz, which is well below the predicted value
Keywords
AC-DC power convertors; calibration; electric current measurement; measurement standards; 100 kHz; ac-dc current calibration; leakage current; thermal current converters; Analog-digital conversion; Calibration; Circuits; Computer errors; Frequency estimation; Impedance; Joining processes; Leakage current; Position measurement; Resistance heating;