• DocumentCode
    3449721
  • Title

    Optimizing the Series Connection of Thermal Converters For AC-DC Current Difference Calibration - Improved Model

  • Author

    Lind, K. ; Espedalen, J.H. ; Slinde, H.

  • Author_Institution
    Justervesenet
  • fYear
    2004
  • fDate
    38139
  • Firstpage
    585
  • Lastpage
    586
  • Abstract
    When connecting thermal current converters (TCC) in series for calibration of current ac/dc difference, attention has to be paid to the various current leakages that may occur. The series connection has been modelled and a specially designed "T-piece" constructed. Calculations indicate leakage error less than 210-6 in delta at frequencies up to 100 kHz
  • Keywords
    AC-DC power convertors; calibration; electric current measurement; T-piece construction; ac-dc current difference calibration; leakage current; thermal current converters; Analog-digital conversion; Cable shielding; Calibration; Circuits; Frequency; Impedance; Joining processes; Leakage current; Uncertainty; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2004 Conference on
  • Conference_Location
    London
  • Print_ISBN
    0-7803-8494-6
  • Electronic_ISBN
    0-7803-8494-6
  • Type

    conf

  • DOI
    10.1109/CPEM.2004.305391
  • Filename
    4097385