DocumentCode :
344992
Title :
Operation experience of CYCIAE30 injector
Author :
Chu, Cengjie ; Zhang, Tianjue ; Fan, Mingwu
Author_Institution :
China Inst. of Atomic Energy, Beijing, China
Volume :
3
fYear :
1999
fDate :
1999
Firstpage :
1940
Abstract :
A 30 MeV compact cyclotron, CYCIAE30 has been working as a supplier of medium and short live time radioactive isotopes for more than four years. To meet the increasing requirements of medical isotopes, it is asked that the machine should continuously run at a high level of beam intensity. But last September, it was difficulty to get the beam more than 100 μA. Some troubles came from the injector were found in the injection system. In this paper, the injection system and the existing problem will be described briefly and the proposal to improve the injection system is given
Keywords :
biomedical equipment; cyclotrons; particle beam injection; radioisotopes; 30 MeV; CYCIAE30 injector; compact cyclotron; medical isotopes; operation experience; radioactive isotopes; Acceleration; Cyclotrons; Electrodes; Electrostatics; Ion sources; Isotopes; Magnetic fields; Magnetostatics; Particle beam injection; Radio frequency;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1999. Proceedings of the 1999
Conference_Location :
New York, NY
Print_ISBN :
0-7803-5573-3
Type :
conf
DOI :
10.1109/PAC.1999.794321
Filename :
794321
Link To Document :