Abstract :
The open-loop characteristic of the double magnetic detector is calculated in theory based on harmonic balance principle and compared with the testing result. The study shows that the open-loop characteristic of the double magnetic detector has only one operating point corresponding to zero ampere turns, no other zero output points so called false-balance points
Keywords :
comparators (circuits); electric current measurement; sensors; double magnetic detector comparator; false-balance points; harmonic balance principle; open-loop characteristic; Detectors; Linearity; Magnetic analysis; Magnetic circuits; Magnetic cores; Magnetic flux; Magnetic modulators; Magnetic properties; Magnetization; Nonlinear circuits;