  • Abstract
    A VME based single turn beam position monitor has been developed to improve diagnostics for the NSLS UV ring. A monopulse network processes the PUE pulses, generating the sum and difference signals. An analog processing board amplifies, rectifies, and holds the signals. A digital board then digitizes and stores the data. The system can measure 32,000 turns of bipolar PUE signals from button type electrodes (1 nS per lobe) at a 170 nS repetition rate, with bunches separated by 18.9 nS. The system makes useful measurements over a 40 dB dynamic range of beam current. At full current the resolution is 50 microns
  • Keywords
    electron accelerators; nuclear electronics; particle beam diagnostics; storage rings; system buses; NSLS UV ring; PUE pulses; VME based single turn beam position monitor; analog processing board; bipolar PUE signals; button type electrodes; difference signals; digital board; electron storage rings; monopulse network; self triggered single turn beam position monitor; sum signals; Current measurement; Dynamic range; Electrodes; Electron beams; Monitoring; Pulse amplifiers; Pulse generation; Signal generators; Signal processing; Signal resolution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1999. Proceedings of the 1999
  • Conference_Location
    New York, NY
  • Print_ISBN
    0-7803-5573-3
  • Type

    conf

  • DOI
    10.1109/PAC.1999.794379
  • Filename
    794379