DocumentCode
345042
Title
Self triggered, single turn beam position monitor for electron storage rings
Author
Rothman, J. ; Michta, R. ; Nawrocky, R. ; Batrakov, A. ; Shilo, V. ; Kuznetsov, S.
Author_Institution
Brookhaven Nat. Lab., Upton, NY, USA
Volume
3
fYear
1999
fDate
1999
Firstpage
2081
Abstract
A VME based single turn beam position monitor has been developed to improve diagnostics for the NSLS UV ring. A monopulse network processes the PUE pulses, generating the sum and difference signals. An analog processing board amplifies, rectifies, and holds the signals. A digital board then digitizes and stores the data. The system can measure 32,000 turns of bipolar PUE signals from button type electrodes (1 nS per lobe) at a 170 nS repetition rate, with bunches separated by 18.9 nS. The system makes useful measurements over a 40 dB dynamic range of beam current. At full current the resolution is 50 microns
Keywords
electron accelerators; nuclear electronics; particle beam diagnostics; storage rings; system buses; NSLS UV ring; PUE pulses; VME based single turn beam position monitor; analog processing board; bipolar PUE signals; button type electrodes; difference signals; digital board; electron storage rings; monopulse network; self triggered single turn beam position monitor; sum signals; Current measurement; Dynamic range; Electrodes; Electron beams; Monitoring; Pulse amplifiers; Pulse generation; Signal generators; Signal processing; Signal resolution;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1999. Proceedings of the 1999
Conference_Location
New York, NY
Print_ISBN
0-7803-5573-3
Type
conf
DOI
10.1109/PAC.1999.794379
Filename
794379
Link To Document