    1.5 Micron Acetylene Stabilised Frequency Standard and the Measurement of its Absolute Frequency using an Optical Frequency Comb

  • Author

    Czajkowski, Andrzej ; Madej, A.A. ; Bernard, J.

  • Author_Institution
    Dept. of Phys., Ottawa Univ., Ont.
  • fYear
    2004
  • fDate
    38139
  • Firstpage
    670
  • Lastpage
    671
  • Abstract
    Frequencies of the P(10), P(l 1), P(15), P(16), P(20), and P(21) transitions in the v1 + v3 overtone band of 13C2H2 were determined using an optical frequency comb generator. The laser frequency showed a stability of 4 times 10-12 in 1 s and a reproducibility of better than 1 kHz
  • Keywords
    frequency measurement; measurement standards; optical variables measurement; organic compounds; 1.5 micron; absolute frequency; acetylene stabilised frequency standard; optical frequency comb generator; overtone band; Councils; Diode lasers; Frequency measurement; Laser stability; Laser transitions; Measurement standards; Optical saturation; Reproducibility of results; Ultrafast optics; Wavelength division multiplexing;
  • fLanguage
    English