Abstract :
The new Fermilab 8-GeV transfer line for the Main Injector is now commissioned. Studies had been done to measure the optical characteristics of the beamline. In order to capture the state of the beamline as completely as possible all accelerator data, i.e. Beam Position Monitor, Multiwire Profile Monitor, magnet current, and other miscellaneous information, were read and saved. A recently developed beamline analysis program was used to collect data and to do the analysis. Orbit data was used to understand the beamline quadrupole strengths and to measure the dispersion function. The profile data was used to extract beam emittances and to estimate the initial lattice parameter of the beamline
Keywords :
beam handling equipment; ion optics; particle beam diagnostics; proton beams; 8 GeV; Beam Position Monitor; Fermilab Main Injector 8-GeV transfer line; Multiwire Profile Monitor; beam emittances; beamline analysis program; beamline quadrupole strengths; dispersion function; initial lattice parameter; magnet current; optics measurement; Accelerator magnets; Data mining; Dispersion; Extraterrestrial measurements; Lattices; Magnetic analysis; Magnetic separation; Monitoring; Orbital calculations; Permanent magnets;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1999. Proceedings of the 1999
Conference_Location :
New York, NY
Print_ISBN :
0-7803-5573-3
Type :
conf
DOI :
10.1109/PAC.1999.795333
Filename :
795333
Link To Document :
بازگشت