• DocumentCode
    345379
  • Title

    Optimization of the parameters in the RHIC single crystal heavy ion collimation

  • Author

    Biryukov, V.M. ; Chesnokov, Y.A. ; Kotov, V.I. ; Trbojevic, D. ; Stevens, A.

  • Author_Institution
    Inst. of High Energy Phys., Protvino, Russia
  • Volume
    2
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    1237
  • Abstract
    In the framework of the project to design and test a collimation system prototype using a bent channeling crystal for cleaning of the RHIC heavy ion beam halo, we have studied the optimal length and bending angle of a silicon (110) single crystal proposed to be a primary element situated upstream of the traditional heavy amorphous collimator. Besides the matters of the channeling and collimation efficiency, we also looked into the impact the crystal may have on the non-channeled particles that go on circulating in the ring, so as to reduce the momentum offset of the particles scattered of the crystal
  • Keywords
    beam handling equipment; channelling; colliding beam accelerators; ion accelerators; optimisation; synchrotrons; RHIC single crystal heavy ion collimation; Relativistic Heavy Ion Collider; beam halo; bent channeling crystal; momentum offset; optimization; prototype; Cleaning; Collimators; Crystals; Gold; Ion beams; Particle beams; Particle scattering; Particle tracking; Silicon; System testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1999. Proceedings of the 1999
  • Conference_Location
    New York, NY
  • Print_ISBN
    0-7803-5573-3
  • Type

    conf

  • DOI
    10.1109/PAC.1999.795507
  • Filename
    795507