DocumentCode :
3454141
Title :
An ultrasound study of immunochemical systems
Author :
Sarvazyan, A.P. ; Shilnikow, G.V. ; Priev, A.I.
Author_Institution :
Inst. of Biol. Phys., Acad. of Sci., Moscow, USSR
fYear :
1988
fDate :
2-5 Oct 1988
Firstpage :
919
Abstract :
The specific increment of ultrasound velocity in aqueous solutions of immunoglobulin G (IgG) and their fragments, extracted from different mammals, was measured. The changes in the acoustic characteristics of solutions during antigen-antibody reactions were investigated. It was shown that the formation of an immune complex in the insulin-antibody reaction leads to a substantial increase in the ultrasound velocity
Keywords :
bioacoustics; molecular biophysics; proteins; solutions; ultrasonic velocity; IgG; antigen-antibody reactions; aqueous solutions; immunochemical systems; immunoglobulin G; ultrasound velocity; Acoustic measurements; Biosensors; Immune system; Mice; Physics; Solvents; Surface waves; Ultrasonic imaging; Ultrasonic variables measurement; Velocity measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium, 1988. Proceedings., IEEE 1988
Conference_Location :
Chicago, IL
Type :
conf
DOI :
10.1109/ULTSYM.1988.49510
Filename :
49510
Link To Document :
بازگشت