Title :
BGO shield electronics in VXIbus standard
Author :
Bosson, G. ; Foglio, R. ; Patti, A. ; Pouxe, J. ; Tournier, M. ; Karkour, N. ; Deschamps, J. ; Humbert, B. ; Ring, C. ; Clément, J. ; Wilkinson, L.
Author_Institution :
ISN, Grenoble, France
Abstract :
Electronics for six EUROGAM BGO shields is integrated onto one VXI (VME extension for instrumentation) D-size module. For each of the six shields, time and energy measurements are processed. As each shield consists of 10 BGO detectors, a ´hit´ pattern of the BGO detectors is also built. The output of the very-low-energy discriminator for the anti-Compton shield is transmitted, via the VXI local bus lines, to the corresponding Ge channel in the neighboring VXI module to allow fast suppression to take place.<>
Keywords :
bismuth compounds; computerised instrumentation; nuclear electronics; nuclear instrumentation; physics computing; scintillation counters; BGO detectors; Be/sub 4/Ge/sub 3/O/sub 12/; D-size module; EUROGAM BGO shields; VXI local bus lines; anti-Compton shield; energy measurements; fast suppression; time measurements; very-low-energy discriminator; Aluminum; Assembly; Bismuth; Coaxial cables; Crystals; Detectors; Energy measurement; Multiplexing; Nuclear electronics; Preamplifiers;
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference, 1991., Conference Record of the 1991 IEEE
Conference_Location :
Santa Fe, NM, USA
Print_ISBN :
0-7803-0513-2
DOI :
10.1109/NSSMIC.1991.258844