A charged-particle detector telescope array consisting of large-area 2.5-mm-thick Si(Li) Delta E detectors backed by approximately 50 mm*150 mm BGO scintillator-PMT (photomultiplier tube) E detectors has been developed, calibrated, and used to detect energetic fragments from collisions of 85 MeV/u /sup 20/Ne on Ta. The BGO can provide fast timing information (<1 ns full width at half maximum) for additional particle identification, coincidence measurements, etc. The BGO scintillators were made at the Shanghai Institute of Ceramics as part of an ongoing R&D program which also includes development of radiation-hard BaF/sub 2/ and BGO.<>
Keywords :
bismuth compounds; coincidence techniques; scintillation counters; semiconductor counters; silicon; BGO scintillators; Be/sub 4/Ge/sub 3/O/sub 12/; Si:Li; charged-particle detector telescope array; coincidence measurements; energetic fragments; fast timing information; particle identification; Ceramics; Current measurement; Detectors; Energy measurement; Particle measurements; Photomultipliers; Power measurement; Sensor arrays; Telescopes; Timing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference, 1991., Conference Record of the 1991 IEEE
Conference_Location :
Santa Fe, NM, USA
Print_ISBN :
0-7803-0513-2
Type :
conf
DOI :
10.1109/NSSMIC.1991.258869
Filename :
258869
Link To Document :
بازگشت